返回首页

保定市配电柜厂

本站导航

新闻动态

当前位置:网站首页 > 新闻动态 > 详细信息
电缆芯线截面的选择还应符合下列要
添加时间:2021/8/5 16:12:58     浏览次数:
电缆芯线截面的选择还应符合下列要求:
The selection of cable core section shall also meet the following requirements:
(1)电流回路:应使电流互感器的工作准确等级,此时,如无可靠根据,可按断路器的电流容量确定最大短路电流。
(1) current circuit: the working accuracy level of current transformer shall be ensured. At this time, if there is no reliable basis, the maximum short-circuit current can be determined according to the current capacity of the circuit breaker.
(2)电压回路:当全部保护装置和安全自动装置动作时(考虑到发展,电压互感器的负荷最大时),电压互感器至保护和自动装置屏的电缆压降假山制作 不锈钢铸件 铝箔真空袋 七孔梅花管 hdpe硅芯管 液压钢坝 PVC软管 飞行激光打标机 沥青保温泵不应超过额定电压的3%。
(2) voltage circuit: when all protective devices and automatic safety devices act (considering the development, the maximum load of voltage transformer), the cable voltage drop from the voltage transformer to the protection and automatic device panel shall not exceed 3% of the rated voltage.
(3)操作回路:在最大负荷下,操作母线至设备的电压降,不应超过10%额定电压。
(3) operation circuit: under the maximum load, the voltage drop from the operation bus to the equipment shall not exceed 10% of the rated voltage
上一页  高压配电柜是指用于电力系统发电、输电、配电、电能转换和消耗中起通断、控制或保护等作用  
下一页  高压配电柜送电流程:
  • 关于我们
  • 新闻动态
  • 案例展示
  • 网上订单
  • 联系我们
  • 产品分类1
  • 产品分类2
  • 产品分类3

Copyright © 技术支持:遨游网络

  • 联系我们
  • 网上订单
  • 工程案例
  • 本站导航

搜索

  • 关于我们
  • 新闻动态
  • 案例展示
  • 网上订单
  • 联系我们
  • 产品分类1
  • 产品分类2
  • 产品分类3